Ex FLUORESCENT LIGHT FITTINGS, EMERGENCY LIGHT FITTING
Fluorescent light fitting SIF
CONSTRUCTION
Housing: Epoxi/polyester powder-coated sheet steel
Diffuser: flat borosilicate glass with a high thermal and mechanical stability
Gasket: EPDM formed gasket
All-pole are disconnected via NC switch when glass cover is opened.
The light fitting is normally supplied without light sources, two Ex e cable glands M25, one Ex e plug
M25 and with two ring screw M8 (pendant version).
Apparatus category: | II 2GD |
Explosion protection: | Ex db eb mb IIC T4 Gb Ex tb IIIC T80°C Db |
Enviroment temperature: | -30°C ÷ +50°C |
Degree of protection: | IP66 |
Rated voltage: | 220-240 V |
Zone 1,2,21,22
● T8 fluorescent lamps in parallel configuration
● Switch with safety lock; when opening the central lock, all poles of the volt-age supply to the ballast are disconnected
● In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply
● Recessed mounting set for clear rooms
Fluorescent light fitting PSF
CONSTRUCTION
Housing: SMC polyester plastic reinforced with glass fiber, color RAL 7038
Diffuser: PC polycarbonate plastic
Gasket: silicone
Central locking: can be opened/closed using a socket key SW8, hinged lamp cover
The light fitting is normally supplied without light sources, socket key screw, two Ex e cable glands M25, two Ex e plugs M25 and with four ring screw M8 (pendant version).
Apparatus category: |
II 2GD, IM2 |
Explosion protection: |
Ex d e mb IIC T4 Gb |
Enviroment temperature: |
-20ºC ≤ Ta ≤ +50ºC [ATEX] |
Degree of protection: |
IP66 |
Rated voltage: |
220-240 V |
Zone 1,2,21,22
● T8 fluorescent lamps in parallel configuration
● Central locking
● Switch with safety lock; when opening the central lock, all poles of the volt-age supply to the ballast are discon-nected
● In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply.
Fluorescent light fitting FLX
CONSTRUCTION
Housing: corrosion resistant grey polyurethanes painted aluminium
Diffuser: borosilicate glass tube
Gasket: silicon
The light fitting is normally supplied with two light sources, two entries M20 and wall/sealing mounting set.
Apparatus category: | II 2GD |
Explosion protection: | Ex db eb IIC T5/T6 Gb Ex tb IIIC T80°C Db |
Enviroment temperature: | -20ºC ≤ Ta ≤ +50ºC [ATEX] -50ºC ≤ Ta ≤ +50ºC [EAC] |
Degree of protection: | IP66 |
Rated voltage: | 100÷280 V AC/DC |
Zone 1,2,21,22
● TC-TSE fluorescent compact lamps
● 100÷280V AC/DC
● 0-60 Hz
Emergency light fitting FLXE LED
CONSTRUCTION
Housing: aluminium powder painted casting
Diffuser: borosilicate glass tube,
Gasket: silicon
The light fitting is normally supplied with two entries M20 and wall/sealing mounting set
Apparatus category: | II 2GD |
Explosion protection: | Ex db eb op is IIC T6 Gb Ex tb op is IIIC T80°C Db |
Enviroment temperature: | -20°C ÷ +50°C |
Degree of protection: | IP66 |
Rated voltage: | 220-240 V (110V on request) |
Rated autonomy: | > 3 hours |
Battery: | Ni-MH 3,6V/2.2Ah |
Zone 1,2,21,22
● Used for marking escape routes and exits in potentially explosive atmospheres.
● Self-test, monitoring and diagnostics reduce costly maintenance checks.
● >3h autonomy
● Maintained / Non maintained operation
● Possibility of supplies with DALI compatible ballast
● Ni-MH 3,6V/2.2Ah, build in light fitting, microprocessor controlled charging, discharging and control of battery
Emergency light fitting PSF E
The emergency fluorescent light fitting type PSF E is intended for use in places with an explosive gas and dust atmosphere. The light fitting is designed for use in the industrial areas and facilities, indoor and outdoor spaces.
Ex fluorescent light fitting type PSF E is used as emergency light fitting with >1,5h or 3h autonomy.
CONSTRUCTION
Housing: SMC polyester plastic reinforced with glass fiber
Diffuser: PC polycarbonate plastic
Gasket: EPDM formed gasket
Central locking: can be opened/closed using a socket key SW8, hinged lamp cover
The light fitting is normally supplied without light sources, with socket key, two Ex e cable glands M25, two Ex e plugs M25 and with four ring screw M8 (pendant version).
Apparatus category: | II 2GD |
Explosion protection: | Ex db eb mb IIC T4 Gb Ex tb IIIC T80°C Db |
Enviroment temperature: | -20°C ÷ +40°C |
Degree of protection: | IP66 |
Rated voltage: | 220-240 V |
Rated autonomy: | 1,5h or 3h |
Battery: | Ni-Mh Saft VHT D, 4,8V 6Ah
Ni-Mh Saft VHT F, 4,8V 10Ah |
Zone 1,2,21,22
● 1,5 or 3h autonomy
● Maintained / Non maintained operation
● Ni-Mh battery